The only agent that thinks for itself

Autonomous Monitoring with self-learning AI built-in, operating independently across your entire stack.

Unlimited Metrics & Logs
Machine learning & MCP
5% CPU, 150MB RAM
3GB disk, >1 year retention
800+ integrations, zero config
Dashboards, alerts out of the box
> Discover Netdata Agents

Centralized metrics streaming and storage

Aggregate metrics from multiple agents into centralized Parent nodes for unified monitoring across your infrastructure.

Stream from unlimited agents
Long-term data retention
High availability clustering
Data replication & backup
Scalable architecture
Enterprise-grade security
> Learn about Parents

Fully managed cloud platform

Access your monitoring data from anywhere with our SaaS platform. No infrastructure to manage, automatic updates, and global availability.

Zero infrastructure management
99.9% uptime SLA
Global data centers
Automatic updates & patches
Enterprise SSO & RBAC
SOC2 & ISO certified
> Explore Netdata Cloud

Deploy Netdata Cloud in your infrastructure

Run the full Netdata Cloud platform on-premises for complete data sovereignty and compliance with your security policies.

Complete data sovereignty
Air-gapped deployment
Custom compliance controls
Private network integration
Dedicated support team
Kubernetes & Docker support
> Learn about Cloud On-Premises

Powerful, intuitive monitoring interface

Modern, responsive UI built for real-time troubleshooting with customizable dashboards and advanced visualization capabilities.

Real-time chart updates
Customizable dashboards
Dark & light themes
Advanced filtering & search
Responsive on all devices
Collaboration features
> Explore Netdata UI

Monitor on the go

Native iOS and Android apps bring full monitoring capabilities to your mobile device with real-time alerts and notifications.

iOS & Android apps
Push notifications
Touch-optimized interface
Offline data access
Biometric authentication
Widget support
> Download apps

The future of infrastructure observability

See our strategic direction across AI-native observability, full-stack signals, operational intelligence, and enterprise platform maturity.

AI-native observability
Full-stack signal coverage
Operational intelligence
Enterprise platform maturity
Agent releases every 6 weeks
Cloud continuous delivery
> Explore Product Roadmap

Best energy efficiency

True real-time per-second

100% automated zero config

Centralized observability

Multi-year retention

High availability built-in

Zero maintenance

Always up-to-date

Enterprise security

Complete data control

Air-gap ready

Compliance certified

Millisecond responsiveness

Infinite zoom & pan

Works on any device

Native performance

Instant alerts

Monitor anywhere

AI-native observability

Continuous delivery

Open source foundation

80% Faster Incident Resolution

AI-powered troubleshooting from detection, to root cause and blast radius identification, to reporting.

True Real-Time and Simple, even at Scale

Linearly and infinitely scalable full-stack observability, that can be deployed even mid-crisis.

90% Cost Reduction, Full Fidelity

Instead of centralizing the data, Netdata distributes the code, eliminating pipelines and complexity.

See and Map Your Entire Network

Live topology, flow analytics, and SNMP device and trap monitoring — unified with your full-stack observability.

Control Without Surrender

SOC 2 Type 2 certified with every metric kept on your infrastructure.

Integrations

800+ collectors and notification channels, auto-discovered and ready out of the box.

800+ data collectors
Auto-discovery & zero config
Cloud, infra, app protocols
Notifications out of the box
> Explore integrations
Real Results
46% Cost Reduction

Reduced monitoring costs by 46% while cutting staff overhead by 67%.

— Leonardo Antunez, Codyas

Zero Pipeline

No data shipping. No central storage costs. Query at the edge.

From Our Users
"Out-of-the-Box"

So many out-of-the-box features! I mostly don't have to develop anything.

— Simon Beginn, LANCOM Systems

No Query Language

Point-and-click troubleshooting. No PromQL, no LogQL, no learning curve.

Enterprise Ready
67% Less Staff, 46% Cost Cut

Enterprise efficiency without enterprise complexity—real ROI from day one.

— Leonardo Antunez, Codyas

SOC 2 Type 2 Certified

Zero data egress. Only metadata reaches the cloud. Your metrics stay on your infrastructure.

Full Coverage
800+ Collectors

Auto-discovered and configured. No manual setup required.

Any Notification Channel

Slack, PagerDuty, Teams, email, webhooks—all built-in.

Built for the People Who Get Paged

Because 3am alerts deserve instant answers, not hour-long hunts.

Every Industry Has Rules. We Master Them.

See how healthcare, finance, and government teams cut monitoring costs 90% while staying audit-ready.

Monitor Any Technology. Configure Nothing.

Install the agent. It already knows your stack.
From Our Users
"A Rare Unicorn"

Netdata gives more than you invest in it. A rare unicorn that obeys the Pareto rule.

— Eduard Porquet Mateu, TMB Barcelona

99% Downtime Reduction

Reduced website downtime by 99% and cloud bill by 30% using Netdata alerts.

— Falkland Islands Government

Real Savings
30% Cloud Cost Reduction

Optimized resource allocation based on Netdata alerts cut cloud spending by 30%.

— Falkland Islands Government

46% Cost Cut

Reduced monitoring staff by 67% while cutting operational costs by 46%.

— Codyas

Real Coverage
"Plugin for Everything"

Netdata has agent capacity or a plugin for everything, including Windows and Kubernetes.

— Eduard Porquet Mateu, TMB Barcelona

"Out-of-the-Box"

So many out-of-the-box features! I mostly don't have to develop anything.

— Simon Beginn, LANCOM Systems

Real Speed
Troubleshooting in 30 Seconds

From 2-3 minutes to 30 seconds—instant visibility into any node issue.

— Matthew Artist, Nodecraft

20% Downtime Reduction

20% less downtime and 40% budget optimization from out-of-the-box monitoring.

— Simon Beginn, LANCOM Systems

Pay per Node. Unlimited Everything Else.

One price per node. Unlimited metrics, logs, users, and retention. No per-GB surprises.

Free tier—forever
No metric limits or caps
Retention you control
Cancel anytime
> See pricing plans

What's Your Monitoring Really Costing You?

Most teams overpay by 40-60%. Let's find out why.

Expose hidden metric charges
Calculate tool consolidation
Customers report 30-67% savings
Results in under 60 seconds
> See what you're really paying

Your Infrastructure Is Unique. Let's Talk.

Because monitoring 10 nodes is different from monitoring 10,000.

On-prem & air-gapped deployment
Volume pricing & agreements
Architecture review for your scale
Compliance & security support
> Start a conversation

Monitoring That Sells Itself

Deploy in minutes. Impress clients in hours. Earn recurring revenue for years.

30-second live demos close deals
Zero config = zero support burden
Competitive margins & deal protection
Response in 48 hours
> Apply to partner

Per-Second Metrics at Homelab Prices

Same engine, same dashboards, same ML. Just priced for tinkerers.

Community: Free forever · 5 nodes · non-commercial
Homelab: $90/yr · unlimited nodes · fair usage
> Get the Homelab Plan

$1,000 Per Referral. Unlimited Referrals.

Your colleagues get 10% off. You get 10% commission. Everyone wins.

10% of subscriptions, up to $1,000 each
Track earnings inside Netdata Cloud
PayPal/Venmo payouts in 3-4 weeks
No caps, no complexity
> Get your referral link
Cost Proof
40% Budget Optimization

"Netdata's significant positive impact" — LANCOM Systems

Calculate Your Savings

Compare vs Datadog, Grafana, Dynatrace

Savings Proof
46% Cost Reduction

"Cut costs by 46%, staff by 67%" — Codyas

30% Cloud Bill Savings

"Reduced cloud bill by 30%" — Falkland Islands Gov

Enterprise Proof
"Better Than Combined Alternatives"

"Better observability with Netdata than combining other tools." — TMB Barcelona

Real Engineers, <24h Response

DPA, SLAs, on-prem, volume pricing

Why Partners Win
Demo Live Infrastructure

One command, 30 seconds, real data—no sandbox needed

Zero Tickets, High Margins

Auto-config + per-node pricing = predictable profit

Homelab Ready
Free Video Course

8-episode Netdata tutorial by LearnLinux.tv

76k+ GitHub Stars

3rd most starred monitoring project

Worth Recommending
Product That Delivers

Customers report 40-67% cost cuts, 99% downtime reduction

Zero Risk to Your Rep

Free tier lets them try before they buy

AI Support Assistant, Available 24/7

Nedi has access to all official documentation, source code, and resources. Ask any question about Netdata—responds in your language.

Deployment & configuration
Troubleshooting & sizing
Alerts & notifications
Evidence-based answers
> Ask Nedi now

Never Fight Fires Alone

Docs, community, and expert help—pick your path to resolution.

Learn.netdata.cloud docs
Discord, Forums, GitHub
Premium support available
> Get answers now

60 Seconds to First Dashboard

One command to install. Zero config. 850+ integrations documented.

Linux, Windows, K8s, Docker
Auto-discovers your stack
> Read our documentation

76,000+ Engineers Strong

615+ contributors. 1.5M daily downloads. One mission: simplify observability.

Per-Second. 90% Cheaper. Data Stays Home.

Side-by-side comparisons: costs, real-time granularity, and data sovereignty for every major tool.

See why teams switch from Datadog, Prometheus, Grafana, and more.

> Browse all comparisons
Edge-Native Observability, Born Open Source
Per-second visibility, ML on every metric, and data that never leaves your infrastructure.
Founded in 2016
615+ contributors worldwide
Remote-first, engineering-driven
Open source first
> Read our story
Promises We Publish—and Prove
12 principles backed by open code, independent validation, and measurable outcomes.
Open source, peer-reviewed
Zero config, instant value
Data sovereignty by design
Aligned pricing, no surprises
> See all 12 principles
Edge-Native, AI-Ready, 100% Open
76k+ stars. Full ML, AI, and automation—GPLv3+, not premium add-ons.
76,000+ GitHub stars
GPLv3+ licensed forever
ML on every metric, included
Zero vendor lock-in
> Explore our open source
Build Real-Time Observability for the World
Remote-first team shipping per-second monitoring with ML on every metric.
Remote-first, fully distributed
Open source (76k+ stars)
Challenging technical problems
Your code on millions of systems
> See open roles
Meet the Team Behind Netdata
Conferences, meetups, and tradeshows where you can see Netdata in action and talk to the engineers who build it.
Live demos and deep dives
Book 1-on-1 meetings
Talks and panel sessions
Event recaps and photos
> See all events
Talk to a Netdata Human in <24 Hours
Sales, partnerships, press, or professional services—real engineers, fast answers.
Discuss your observability needs
Pricing and volume discounts
Partnership opportunities
Media and press inquiries
> Book a conversation
Your Data. Your Rules.
On-prem data, cloud control plane, transparent terms.
Trust & Scale
76,000+ GitHub Stars

One of the most popular open-source monitoring projects

SOC 2 Type 2 Certified

Enterprise-grade security and compliance

Data Sovereignty

Your metrics stay on your infrastructure

Validated
University of Amsterdam

"Most energy-efficient monitoring solution" — ICSOC 2023, peer-reviewed

ADASTEC (Autonomous Driving)

"Doesn't miss alerts—mission-critical trust for safety software"

Community Stats
615+ Contributors

Global community improving monitoring for everyone

1.5M+ Downloads/Day

Trusted by teams worldwide

GPLv3+ Licensed

Free forever, fully open source agent

Why Join?
Remote-First

Work from anywhere, async-friendly culture

Impact at Scale

Your work helps millions of systems

$ guides / vmware-vsphere / vmware-vsphere-host-swapping

Operations Guides

vSphere host swapping (SWCUR/SWW/s): hypervisor swap and the memory death spiral

When SWR/s is sustained above zero on an ESXi host, the VMkernel is actively reading VM memory pages back from .vswp files on the datastore. That is not a warning state. It is an active performance emergency. Every swapped-in page costs roughly 100x DRAM latency, and the swap I/O itself competes with VM disk I/O on the same datastore, producing a double penalty that degrades every VM on the host simultaneously.

The critical distinction operators miss: SWCUR being non-zero only means pages were swapped out at some point. Those pages may never be touched again. The performance killer is SWR/s (swap-in rate). When a VM accesses a swapped page, the VMkernel must read it back from disk before the guest instruction can proceed. The guest stalls, the application stalls, and if enough VMs are stalling, the datastore saturates.

What this means

ESXi reclaims memory through a four-tier hierarchy, invoked in order of increasing desperation:

  1. Transparent Page Sharing (TPS) deduplicates identical memory pages. Inter-VM TPS is disabled by default for security reasons, so only intra-VM page sharing occurs in practice.
  2. Ballooning inflates the vmmemctl driver inside the guest, forcing the guest OS to page internally using its own swap or pagefile.
  3. Compression packs pages into a per-VM compression cache. Pages that compress to a small enough size stay in DRAM at higher access latency rather than going to disk.
  4. Host-level swapping writes VM memory pages to .vswp files on the datastore. This is the last resort.

When the host reaches tier 4, it has exhausted every gentler option. Each swapped page lives on a datastore (potentially a shared SAN), and every swap-in or swap-out I/O competes with normal VM disk I/O. The latency impact is catastrophic compared to DRAM, and the I/O contention creates a feedback loop.

The death spiral: swapping generates I/O, I/O latency causes applications to hold in-flight operations in memory longer (timeouts, retries, connection holds), the increased memory retention causes more pressure, which causes more swapping. This can happen in minutes during a workload spike. Memory degradation is cliff-edge, not gradual. The balloon-to-compress-to-swap transition can occur faster than a 5-minute polling interval can capture.

flowchart TD
    A[Host memory pressure] --> B[TPS: intra-VM dedup]
    B -->|insufficient| C[Ballooning: vmmemctl inflates]
    C -->|insufficient or Tools not running| D[Compression: ZIP/s]
    D -->|compression cache full| E[Swap OUT to .vswp: SWW/s]
    E -->|VM touches swapped page| F[Swap IN from .vswp: SWR/s]
    F --> G[Datastore I/O contention]
    G --> H[App latency and timeouts]
    H --> A

If you see swap activity with balloon at zero, VMware Tools is not running or the balloon driver is disabled. The host skipped directly to swap. This is the worst-case path because the host lost its gentlest reclamation tool and went straight to the most expensive one.

VMkernel swap is distinct from and additive to guest-internal swap. Ballooning forces the guest to page internally, and the host may also swap pages to .vswp. Both can happen simultaneously. A VM can suffer guest-internal paging (invisible to ESXi) and VMkernel swap (invisible to the guest) at the same time, compounding the latency penalty.

Common causes

CauseWhat it looks likeFirst thing to check
Severe memory overcommitmentBalloon rising, then compression, then swap across multiple VMs. Host consumed memory near physical RAM.Host memory consumed vs. physical capacity.
VMware Tools not runningMCTLSZ at zero while SWCUR > 0. Host skipped ballooning entirely.Tools status on affected VMs.
Memory limit set on VMSwap on a single VM despite host having free memory. MCTLSZ may be zero for that VM.VM memory limit setting (sched.mem.max).
DRS imbalanceOne host swapping while others have headroom. DRS not migrating VMs off the pressured host.Per-host memory consumed across cluster.
VM memory leakSingle VM consumed memory climbing steadily. Balloon and swap concentrate on that VM.Per-VM active vs. consumed memory trend.
Mass VM boot or power-onTransient swap spike during boot storm. Balloon and compression may also spike briefly.Whether swap sustains after boot completes.

Quick checks

These are read-only commands safe to run on any ESXi host or from a PowerCLI session.

# esxtop memory view: press 'm', look at SWCUR, SWR/s, SWW/s
# Press 'f' to add fields if any are missing
esxtop

# Host-level swap rates via PowerCLI (realtime, 20s interval)
Get-VMHost | Get-Stat -Stat mem.swapinRate.average -Realtime -MaxSamples 1
Get-VMHost | Get-Stat -Stat mem.swapoutRate.average -Realtime -MaxSamples 1

# Total swapped memory (cumulative snapshot, not a rate)
Get-VMHost | Get-Stat -Stat mem.swapped.average -Realtime -MaxSamples 1

# Balloon status per VM via PowerCLI
Get-VM | Select Name, @{N='BalloonedMB';E={$_.ExtensionData.Summary.QuickStats.BalloonedMemory}}

# VMware Tools status on all VMs
Get-VM | Select Name, @{N='ToolsStatus';E={$_.ExtensionData.Guest.ToolsRunningStatus}}

# Datastore latency where .vswp files reside
# In esxtop, press 'u' for disk device view, look at GAVG/KAVG/DAVG
esxtop

How to diagnose it

  1. Confirm it is VMkernel swap, not guest-internal swap. Open esxtop, press m, and look at SWR/s. If it is non-zero, VMkernel swap-in is happening. Guest-internal swap does not appear here. Check inside the guest OS (pagefile usage on Windows, si/so columns in vmstat on Linux) to assess guest-internal paging separately.

  2. Check balloon status alongside swap. If MCTLSZ is zero or near-zero while SWCUR is climbing, the balloon driver is not working. The most common reasons are VMware Tools not installed, Tools not running, or the balloon driver explicitly disabled. Verify Tools status first.

  3. Check if a VM memory limit is forcing swap. A VM with sched.mem.max set below its configured memory can be forced to swap to .vswp even when the host has ample free memory. This is documented VMware behavior. Check the VM resource settings and any parent resource pool limits.

  4. Compare SWCUR to SWTGT. SWTGT is the swap target computed by the memory scheduler. If SWTGT is greater than SWCUR, the VMkernel is actively trying to swap more pages out. If SWTGT is less than SWCUR, the host is working to unswap pages back into DRAM.

  5. Check datastore latency on the datastore holding the .vswp files. In esxtop, press u and look at DAVG, KAVG, and GAVG for the device backing the datastore. Swap I/O adds load. If KAVG is elevated while DAVG is moderate, the VMkernel queue is absorbing swap I/O pressure.

  6. Identify which VMs are being swapped most heavily. Sort by SWCUR in esxtop memory view. The VMs with the highest SWCUR combined with non-zero SWR/s are the ones experiencing active pain.

  7. Check for the compression precursor. Look at ZIP/s and UNZIP/s in esxtop memory view. If compression is active alongside swap, the host is deep in the reclamation cascade and compression alone was insufficient. Compression sustained at non-zero is a TICKET-level signal on its own: the host is in the danger zone between ballooning and swapping.

  8. Distinguish hypervisor swap from ballooning-induced guest swap. If balloon (MCTLSZ) is non-zero and the guest is paging internally, the guest swap is caused by the balloon driver reclaiming memory. This is “gentle” reclamation from the host’s perspective but may be severe from the guest’s. Both can coexist with VMkernel swap. Check guest-internal swap counters to assess total impact.

Metrics and signals to monitor

SignalWhy it mattersWarning sign
SWR/s (swap-in rate)The primary indicator of active swap pain. Any sustained value > 0 means VMs are actively hitting swapped pages.Sustained > 0 for more than 60 seconds is a paging emergency.
SWW/s (swap-out rate)Host is proactively writing pages to .vswp. May precede swap-in.Sustained > 0 without swap-in is a TICKET. With swap-in, it is PAGE.
SWCUR (current swapped)Cumulative snapshot of memory currently swapped out. Does not mean those pages are being accessed.Non-zero means risk. Correlate with SWR/s for active impact. SWCUR does not decrease immediately when pressure lifts.
MCTLSZ (balloon current)Shows whether ballooning was attempted before swap.Zero balloon with active swap means Tools is not working and the host skipped to the worst tier.
ZIP/s (compression rate)Precursor to swap. If compression is active, the host is in the danger zone.Sustained non-zero indicates pressure beyond what ballooning can handle.
KAVG (kernel latency) on .vswp datastoreSwap I/O competes with VM disk I/O. Elevated KAVG shows queue pressure.KAVG > 2ms sustained alongside swap activity.
Host memory consumedShows how close the host is to physical capacity.Approaching 85% of physical RAM. Memory degradation is cliff-edge.
VM active vs. consumed memoryActive memory is what the VM is actually touching. If active approaches consumed, the VM has little reclaimable memory.Active:consumed ratio near 1.0 means balloon and swap will directly hurt the workload.

Fixes

Immediate: reduce pressure on the host

The fastest fix is to vMotion VMs off the pressured host to hosts with available memory. Identify the largest memory consumers (highest consumed or active memory) and migrate them first. This does not fix the underlying overcommitment, but it stops the death spiral.

If vMotion is not available or the cluster is universally pressured, the only immediate options are to suspend non-critical VMs or add physical memory to the host (requiring a reboot). Suspending VMs is disruptive. Document the action and prioritize recovery.

Fix the balloon driver

If MCTLSZ is zero across all VMs while swap is active:

  • Verify VMware Tools (or open-vm-tools) is installed and running on every VM. Use Get-VM | Select Name, @{N='ToolsStatus';E={$_.ExtensionData.Guest.ToolsRunningStatus}}.
  • Check if the balloon driver was explicitly disabled in the VM advanced settings.
  • Update Tools if it is outdated. A crashed or hung Tools process can leave the balloon driver non-functional even though Tools appears installed.

Once Tools is running, the host can use ballooning as the first reclamation tier instead of jumping directly to compression and swap.

Remove memory limits

A VM with a memory limit (sched.mem.max set below configured memory) can be forced to swap even when the host has free memory. This looks like a host-level memory problem but is a per-VM configuration issue.

Check resource settings on affected VMs. Set the memory limit to Unlimited unless there is a specific, documented reason for the cap. The limit may have been inherited from a resource pool or set during testing and never removed.

Reduce VM memory allocations or add host RAM

If the host is genuinely overcommitted (total VM configured memory far exceeds physical RAM, and active memory demand is high), the long-term fix is to either add physical memory or reduce VM allocations. Memory reservations can protect critical VMs from ballooning and swap for the reserved amount, but they reduce the host’s flexibility to overcommit.

Physical RAM across the cluster should be 20-30% above total VM active memory, accounting for N+1 host failure capacity.

Consider host cache or NVMe tiering (version-dependent)

ESXi supports using local SSDs as a write-back cache for .vswp files, reducing swap latency compared to spinning disk or shared SAN. However, swap to host cache is deprecated in vSphere 9.0 and will be removed in a future release. In vSphere 9.0+, NVMe Memory Tiering replaces host cache as the recommended approach for reducing swap latency by using page aging to classify hot and cold pages rather than random page selection.

If you are on vSphere 7.x or 8.x and have local SSDs, enabling host cache can reduce the severity of swap events. It does not eliminate them.

Prevention

  • Monitor reclamation indicators independently. Do not set a single host memory utilization threshold and call it done. Track balloon, compression, and swap as separate signals. A host at 85% consumed memory with zero balloon and zero swap is healthy. A host at 70% with active swap is in crisis.
  • Ensure VMware Tools on every VM. Without Tools, the host loses ballooning and jumps directly to compression and swap. Audit Tools status regularly as part of VM provisioning.
  • Avoid memory limits. Memory limits cause silent, hard-to-diagnose performance degradation. Use reservations if you need to guarantee memory to a VM, not limits to cap it.
  • Track active:consumed memory ratio. If VM active memory consistently approaches consumed memory, the VM has little reclaimable memory and ballooning will force the guest to page actively, degrading performance even before swap begins.
  • Plan for N+1 memory headroom. Losing one host should not push remaining hosts into the reclamation cascade.
  • Watch for boot storms. Mass VM startup after host maintenance, power restoration, or VDI login storms can cause transient memory pressure. Brief swap during boot is expected. Sustained swap after boot completes is not.
  • Review DRS aggressiveness and constraints. If DRS is in manual mode or constrained by affinity rules, it may not migrate VMs off pressured hosts. Verify that DRS can actually rebalance memory across the cluster when a host enters the reclamation cascade.

How Netdata helps

Netdata surfaces the VMkernel swap cascade at high resolution. The balloon-to-compress-to-swap transition can complete in minutes and disappear inside a 5-minute rolled-up average.

  • Swap-in and swap-out rates let you see the exact moment SWR/s transitions from zero to non-zero, rather than discovering it after the spike has been smoothed away by rollup.
  • Correlated balloon, compression, and swap metrics on a single timeline let you verify the reclamation cascade is following the expected order. If swap appears without preceding balloon activity, the anomaly is immediately visible and points to a Tools problem.
  • Datastore latency alongside swap activity shows the I/O contention the swap is creating. Elevated KAVG correlating with SWW/s confirms the double penalty is active.
  • Host memory consumed, active, and ballooned trends over hours and days reveal whether the host is trending toward a cliff-edge event or experiencing a transient spike that will self-resolve.
  • Anomaly detection on memory reclamation metrics can flag unusual balloon or compression patterns before swap begins, giving operators lead time to rebalance the cluster before the death spiral starts.
The Netdata solution

VMware vSphere monitoring with Netdata

Netdata auto-discovers vCenter, ESXi hosts, VMs, and datastores through the vSphere API and collects them per second with ML-powered anomaly detection. Correlate CPU ready and co-stop, ballooning and host swap, datastore latency, and snapshot growth against the host and guest signals behind them, so you catch the incidents in these runbooks before they page anyone.